Monday, 23 November 2026

FDA-Cleared AI Tool Aims to Improve Accuracy of Home Sleep Apnoea Tests

Share:
SAM aims to support more reliable interpretation of the Apnoea-Hypopnoea Index (AHI) and sleep apnea severity

Artificial intelligence and machine learning are opening new possibilities in sleep diagnostics, particularly in improving the accuracy and interpretation of home sleep apnea tests. Addressing a key limitation in conventional home testing, Neurotronics has received US Food and Drug Administration (FDA) 510(k) clearance for its Sleep Analysis Module (SAM), an AI/ML-powered Software as a Medical Device (SaMD) designed to estimate a patient's total sleep time using photoplethysmography (PPG) signals. By providing clinicians with a more accurate estimate of actual sleep duration without requiring additional sensors, SAM aims to support more reliable interpretation of the Apnoea-Hypopnoea Index (AHI) and sleep apnea severity. In this interview with MedTech Spectrum, Andrew Ehrenberg, Director of Marketing and Business Development, Neurology, Nihon Kohden America, and Jake Johnson, President and CEO of Neurotronics, discuss the technology behind SAM, its clinical validation, integration with Neurotronics' NomadAir and Polysmith platforms, and the broader potential of AI/ML in advancing sleep diagnostics.

The FDA's 510(k) clearance for the Sleep Analysis Module (SAM) marks Neurotronics' first FDA-cleared AI/ML-based sleep analysis algorithm. What does this milestone mean for the company's medical technology strategy, and how does it strengthen its position in the evolving sleep diagnostics market?

The Sleep Analysis Module, or SAM, is Neurotronics’ first FDA-cleared AI/ML algorithm, cleared in October 2026 through the 510(k) pathway. It addresses a specific problem: most home sleep apnea tests cannot measure how long the patient actually slept, which can cause sleep-apnea severity to be underestimated. SAM is Software as a Medical Device, or SaMD, so it addresses that problem through regulated software without requiring another sensor.

It is also our first step toward something larger. We are building a clinical-intelligence platform that turns signals clinicians already collect into information they can act on inside the workflow they already use.

With SAM, Neurotronics has taken a clinical problem from concept through development, clinical validation, and regulatory clearance. Integration with NomadAir and Polysmith is now underway.

SAM uses photoplethysmography (PPG) signals to estimate total sleep time (TST) without requiring additional sensors. Could you explain how the algorithm analyzes these signals and what makes this approach different from conventional sleep assessment methods?

SAM analyzes the photoplethysmography, or PPG, signal collected during a study. It looks at patterns in that signal associated with sleep and wakefulness and uses them to estimate the patient’s total sleep time.

The practical difference is simplicity. Conventional sleep staging relies on EEG, EOG, and EMG signals interpreted by a trained scorer. That remains the standard when those signals are available, and SAM is not intended to replace full sleep staging. In home sleep apnea testing, however, those channels often are not collected. SAM can estimate total sleep time from compatible PPG already being recorded, without adding another sensor or making the test more complicated for the patient.

Total recording time is often used as a substitute for actual sleep time in home sleep apnea testing, potentially affecting the calculation of the apnea-hypopnea index (AHI). How can SAM's estimated TST help clinicians interpret AHI and assess obstructive sleep apnea severity more accurately?

AHI is the number of breathing events per hour of sleep. The problem with many home studies is that we do not know exactly how long the patient slept, so recording time is used instead. If the patient was awake for part of the night, that can dilute the index and make the apnea look less severe than it really is.

SAM does not detect the breathing events. It gives the clinician a better estimate of the time the patient was actually asleep. In our clinical evaluation, severity classification agreed with the PSG reference in about 93 per cent of studies using SAM’s estimate, compared with about 75 per cent when total recording time was used.

That gives the clinician better context for interpreting the study and deciding what the result means for that patient.

What clinical validation and performance evaluation were undertaken to support SAM's FDA 510(k) submission? How does Neurotronics ensure the algorithm's accuracy and reliability across different patient populations and variations in sleep patterns?

We validated SAM using 146 adult sleep studies from eight independent sites that were separate from the data used to develop the algorithm. Three experienced sleep technologists scored each study separately, and we compared SAM’s estimate with the result on which at least two of the three scorers agreed.

On average, SAM’s estimate was within about three minutes of the scorers.

Using eight independent sites gave us a broader clinical test than a single-center dataset.

We used in-lab polysomnography because it gives us the strongest reference for when a patient was actually asleep while capturing the same kind of PPG signal available in a compatible home test. That let us evaluate the algorithm against a rigorous clinical reference before bringing it into the home-testing workflow.

SAM will initially be integrated into Polysmith sleep diagnostic software for studies recorded using the NomadAir home sleep apnea testing solution. How will this integration fit into existing clinical workflows, and what benefits could it offer sleep laboratories, healthcare professionals, and patients?

NomadAir records the home sleep apnea study, including compatible PPG. Polysmith is used to review and analyze the study, and SAM adds estimated total sleep time within that environment.

The laboratory will not need to add another sensor, export data to a separate application, open another portal, or build a parallel process. The study is recorded with NomadAir, reviewed in Polysmith, analyzed by SAM, and reported inside the same Neurotronics ecosystem. That gives the laboratory one connected workflow and one accountable technology partner. Clinicians gain better context when interpreting home studies, while patients retain the simplicity and accessibility that make home testing valuable.

We will announce commercial availability once integration is complete.

How do you see AI/ML-based software-only medical devices transforming sleep diagnostics over the next few years? What are Neurotronics' priorities for expanding SAM's capabilities and developing further software-driven diagnostic solutions?

AI/ML in sleep is moving from stand-alone experiments to regulated tools embedded in clinical workflows. The opportunity is to help clinicians get more from physiologic signals, reduce repetitive work, and apply consistent analysis at scale.

Our immediate priority is completing SAM’s integration with Polysmith and NomadAir. From there, we will evaluate additional compatible PPG sources and delivery platforms.

SAM gives us a model we can repeat. We are already developing additional algorithms that can be added to the same Neurotronics workflow as they are clinically validated and cleared. The goal is simple: keep expanding the intelligence available to clinicians without asking them to stitch together separate systems.